Tag: Biocompatibility/ Cytotoxicity

Manoeuvrability and Biocompatibility of Endodontic Tricalcium Silicate-Based Putties Journal Study

Read more

In vitro biocompatibility and oxidative stress profiles of different hydraulic calcium silicate cements

ABSTRACT INTRODUCTION: MTA Plus is a new calcium silicate cement with unknown cytotoxicity characteristics. The objectives of this study were to examine the effect of MTA Plus on the viability, apoptosis/necrosis profile, and oxidative stress levels of rat odontoblastlike cells. METHODS: MDPC-23 cells were exposed to gray and white MTA Plus (GMTAP, WMTAP), gray and […]

Read more

X-ray diffraction analysis of MTA-Plus, MTA-Angelus and DiaRoot BioAggregate

ABSTRACT INTRODUCTION: The purpose of this study was to investigate and compare the crystalline structures of recently released MTA Plus (MTAP), MTA Angelus (MTA-A), DiaRoot BioAggregate (BA) by X-ray diffraction (XRD) analysis. METHODS: Phase analysis was carried out on powder and set forms of tested materials. The powder specimens placed into sample holders that were […]

Read more

Biocompatibility and bioactivity of calcium silicate based endodontic sealers in human dental pulp cells

ABSTRACT INTRODUCTION: Mineral Trioxide Aggregate (MTA) is a calcium silicate-based material. New sealers have been developed based on calcium silicate as MTA Fillapex and MTA Plus. The aim of this study was to evaluate biocompatibility and bioactivity of these two calcium silicate-based sealers in culture of humandental pulp cells (hDPCs). METHODS: The cells were isolated […]

Read more

Human dental pulp cells response to mineral trioxide aggregate (MTA) and MTA Plus: cytotoxicity and gene expression analysis

ABSTRACTINTRODUCTION: The aim of this study is to investigate the cytotoxicity, osteogenic bioactivity and mRNA expression of osteogenic markers of bone morphogenetic protein 2 (BMP-2), osteocalcin (OC) and alkaline phosphatase (ALP) induced by the extracts of set MTA Plus (MTA P) (Avalon Biomed Inc. Bradenton, FL, USA) in comparison with MTA (Angelus, Londrina, PR, Brazil) […]

Read more

Biocompatibility and mineralized nodule formation of Neo MTA Plus and an experimental tricalcium silicate cement containing tantalum oxide

ABSTRACT INTRODUCTION: The aim of this study is to evaluate the biocompatibility and mineralized nodule formation of an experimental tricalcium silicate cement with tantalum oxide (TSC/T2aO5) as radiopacifier, Neo MTA Plus (Avalon Biomed Inc., Bradenton, FL, USA) and MTA (Angelus, Londrina, PR, Brazil) on human osteoblast-like cells (Saos-2). METHODS: Biocompatibility was evaluated by 3-(4,5-dimethyl-thiazoyl)-2,5-diphenyl-tetrazolium bromide […]

Read more

Biocompatibility of New Pulp-capping Materials NeoMTA Plus, MTA Repair HP, and Biodentine on Human Dental Pulp Stem Cells.

ABSTRACT INTRODUCTION: The aim of the present study was to evaluate the in vitro cytotoxicity of MTA Repair HP, NeoMTA Plus, and Biodentine, newbioactive materials used for dental pulp capping, on human dental pulp stem cells (hDPSCs). METHODS: Biological testing was carried out in vitro on hDPSCs. Cell viability and cell migration assays were performed […]

Read more

Cell Viability and Tissue Reaction of NeoMTA Plus: An In Vitro and In Vivo Study

Abstract: The aim of this study was to evaluate the cell viability and tissue reaction of NeoMTA Plus (NMP; Avalon Biomed Inc, Houston, TX) compared with mineral trioxide aggregate (MTA; Angelus, Londrina, PR, Brazil) and Biodentine (BD; Septodont, Saint-Maur-de-Fossés, France). METHODOLOGY:Fibroblasts (3T3) were plated and exposed to 1% extract from the test material before and […]

Read more

Biocompatibility of New Pulp-capping Materials NeoMTA Plus, MTA Repair HP, and Biodentine on Human Dental Pulp Stem Cells

Abstract: The aim of the present study was to evaluate the in vitro cytotoxicity of MTA Repair HP, NeoMTA Plus, and Biodentine, newbioactive materials used for dental pulp capping, on human dental pulp stem cells (hDPSCs). METHODOLOGY: Biological testing was carried out in vitro on hDPSCs. Cell viability and cell migration assays were performed using […]

Read more

Biocompatibility and mineralized nodule formation of Neo MTA Plus and an experimental tricalcium silicate cement containing tantalum oxide.

Abstract: Biocompatibility and mineralized nodule formation of Neo MTA Plus and an experimental tricalcium silicate cement containing tantalum oxide. International Endodontic Journal. AIM: To evaluate the biocompatibility and mineral-ized nodule formation of an experimental tricalcium silicate cement with tantalum oxide (TSC/T2aO5) as radiopacifier, Neo MTA Plus (Avalon Biomed Inc., Bradenton, FL, USA) and MTA (Angelus, […]

Read more
NeoMTA Plus is a stainproof, tricalcium silicate-based bioactive cement that can be used universally for vital pulp and other endodontic indications in primary and permanent teeth. NeoMTA Plus is a bioceramic cement that triggers the healing process. With NeoMTA Plus, general dentists, pediatric dentists, and endodontists now have a superior and reasonably priced bioceramic. Dentists praise the multi-use NeoMTA Plus because it mixes more smoothly, is easier to dispense and the unique gel enables more stable placement, washout resistance and faster clinical setting.

New, stain-free light color:

Ideal for pediatric dentistry—won’t discolor teeth
Liquids such as sodium hypochlorite won’t cause discoloration

Multiple indications:

Pulp-capping to base/liner
Pulpotomies to apexification
Sealer to perforation repair
Root-end filling to resorption

Non-cytotoxic

Inhibits bacterial growth* *Tested in vitro. Not a disinfectant

Grey MTA Plus is a bioceramic tricalcium silicate-based Dental Cement, which is slightly more radiopaque than (white) MTA. The light silvery color of MTA Plus is visible during placement. Grey MTA Plus is indicated for both Vital Pulp Therapy and Endodontic procedures. General dentists and endodontists praise the multi-use Grey MTA Plus because it mixes more smoothly and is easier to dispense. The unique gel enables more stable placement, washout resistance and faster clinical setting.

Multiple indications:

Pulp-capping to Base/Liner
Pulpotomies to Apexification
Sealer to Perforation Repair
Root-end Filling to Resorption

New, light grey color:

More radiopaque than the leading white MTAs
Visible for precise placement
Inhibits bacterial growth in vitro of Staphylococcus aureus, Escherichia coli, Enterococcus faecalis, Pseudomonas aeruginosa.
Non-cytotoxic

Better mixing, handling and placement:

Finer powder mixes more easily and smoothly
Dispense as little as 0.1 gm
Unique gel for stable placement
Washout resistant
No special equipment required

Smart, convenient packaging:

Protects fine powder in desiccant-lined bottle
Easy to dispense powder as needed
Dropper-tip gel bottle minimizes waste